CD16a (FcgRIIIa, V158) cellular binding kit
CD16a (FcgRIIIa, V158) cellular binding assay for ADCC prediction
-->
Cisbio's Human Granzyme B kit is designed for the rapid detection of human Granzyme B in cell supernatant and whole cells.
Granzyme B (also called Cathepsin G-like 1, Cytotoxic T-lymphocyte proteinase 2, Fragmentin-2, Granzyme-2, or Human lymphocyte protein) is found in cytotoxic lymphocytes, NK (natural killer) cells, and cytotoxic T cells. Secreted with Perforin, which creates a pore in the cell membrane, it enters the target cell's cytoplasm and triggers apoptosis through caspase activation.
This kit is designed for the rapid detection of human Granzyme B in cell supernatant and whole cells. The assay enables high throughput without any washing steps, thereby saving time compared to ELISA.
Human Granzyme B is a sandwich immunoassay involving two specific anti-human Granzyme B antibodies, respectively labelled with Europium Cryptate (donor) and d2 (acceptor). The intensity of the signal is proportional to the concentration of Granzyme B present in the sample.
The assay protocol, using a 384-well small volume white plate or a Cisbio low volume 96-well plate (20 µL final), is described on the right. 16 µL of cell supernatant, sample, or standard are dispensed directly into the plate for detection by HTRF reagents. The antibodies labelled with HTRF donor and acceptor can be pre-mixed and added in a single dispensing step to further streamline the assay procedure. The assay can be run in 96- to 384-well plates by simply resizing each addition volume proportionally.
Sample size | 16 µL |
---|---|
Final assay volume | 20 µL |
Kit components | lyophilized standard, frozen detection antibodies, buffers & protocol |
LOD & LOQ (in diluent) | 1.8 ng/mL & 3.7 ng/mL |
Range | 3.7 – 1,500 ng/mL |
Time to result | ON at RT |
Recombinant Granzyme B provided in the kit (standard) was serially diluted in diluent #5, following the procedure given in the kit’s package insert. The HTRF signal, expressed as a delta ratio, was plotted as a function of the Granzyme B concentrations.
intra assay (n=24)
Sample | Mean [GranzymeB] (pg/mL) | CV |
---|---|---|
1 | 644 | 14% |
2 | 438 | 14% |
3 | 23 | 18% |
Mean CV | 15% |
Each of the 3 samples was measured 24 times, and % CV was calculated for each sample.
Inter assay (n=4)
Sample | [GranzymeB] | Mean | CV |
---|---|---|---|
1 | 10 | 576 | 9% |
2 | 54 | 2759 | 6% |
3 | 652 | 18940 | 6% |
Mean CV | 7% |
Each of the samples was measured in 4 different experiments, and % CV was calculated for each sample.
Different cell densities (4K and 2K) of TALL-104 cells (Effector cells) were co-cultured with or without K-562 cells (Target cells) in suspension under 16µL in 384-well sv microplates. The cells were incubated for 16 hours at 37°C - 5% CO2. After co-culture, 4 µL of the HTRF Granzyme B detection reagents were added. The HTRF signal was recorded after an overnight incubation at RT.
Different cell densities (50K and 25K) of TALL-104 cells (Effector cells) were plated in suspension under 50µL in 96-well plates. TALL-104 cells were co-cultured with or without K-562 cells (Target cells) for 16 hours at 37°C - 5% CO2. After co-culture, 16µL of cell supernatants were transferred into a 384-well sv white microplate and 4 µL of the HTRF Granzyme B detection reagents were added. The HTRF signal was recorded after an overnight incubation at RT.
HTRF solutions for each cell type - Flyers
All your HTRF assays in one document! - Catalog
A guide to Homogeneous Time Resolved Fluorescence
General principles of HTRF - Guides
How HTRF compares to Western Blot and ELISA
Get the brochure about technology comparison. - Brochures
Product Insert Granzyme B-2 Kit / 62HGRZBPEG-62HGRZBPEH
62HGRZBPEG-62HGRZBPEH - Product Insert
Innovative solutions in Virology research
Kits and reagents for virology research - Flyers
Advance your CAR-T cell research - Flyers
Safety Data Sheet (DEU) Granzyme B-2 Kit / 62HGRZBPEG
62HGRZBPEG - Safety Data Sheet
Safety Data Sheet (ELL) Granzyme B-2 Kit / 62HGRZBPEG
62HGRZBPEG - Safety Data Sheet
Safety Data Sheet (FRA-FR) Granzyme B-2 Kit / 62HGRZBPEG
62HGRZBPEG - Safety Data Sheet
Safety Data Sheet (ITA) Granzyme B-2 Kit / 62HGRZBPEG
62HGRZBPEG - Safety Data Sheet
Safety Data Sheet (SPA) Granzyme B-2 Kit / 62HGRZBPEG
62HGRZBPEG - Safety Data Sheet
Safety Data Sheet (ENG-GB) Granzyme B-2 Kit / 62HGRZBPEG
62HGRZBPEG - Safety Data Sheet
Safety Data Sheet (ENG-US) Granzyme B-2 Kit / 62HGRZBPEG
62HGRZBPEG - Safety Data Sheet
Safety Data Sheet (DEU) Granzyme B-2 Kit / 62HGRZBPEH
62HGRZBPEH - Safety Data Sheet
Safety Data Sheet (ELL) Granzyme B-2 Kit / 62HGRZBPEH
62HGRZBPEH - Safety Data Sheet
Safety Data Sheet (FRA-FR) Granzyme B-2 Kit / 62HGRZBPEH
62HGRZBPEH - Safety Data Sheet
Safety Data Sheet (ITA) Granzyme B-2 Kit / 62HGRZBPEH
62HGRZBPEH - Safety Data Sheet
Safety Data Sheet (SPA) Granzyme B-2 Kit / 62HGRZBPEH
62HGRZBPEH - Safety Data Sheet
Safety Data Sheet (ENG-GB) Granzyme B-2 Kit / 62HGRZBPEH
62HGRZBPEH - Safety Data Sheet
Safety Data Sheet (ENG-US) Granzyme B-2 Kit / 62HGRZBPEH
62HGRZBPEH - Safety Data Sheet
Choosing the right microplate reader ensures you’ll get an optimal readout. Discover our high performance reader, or verify if your lab equipment is going to be compatible with this detection technology.
Let's find your readerYou might be interested in